Naue Platform 2.0 is a free online calculator in the Naue Portal DesignSuite for designing temporary working platforms and foundation pads that carry tracked construction plant - crawler cranes, piling and drilling rigs and similar equipment. Following the established BR 470 method, it determines the required platform thickness and verifies safety against several limit states: the ultimate limit state (ULS / GZ1) - punching and bearing (slope) failure - and, optionally, the serviceability limit state (SLS / GZ2) - settlement and tilting. Using the track loading, the granular platform properties and a layered subsoil model, and building in the reinforcement effect of Secugrid® geogrids and Combigrid® geocomposites, it delivers a safe, efficient platform design even over weak ground.
Naue Platform 2.0 is used wherever tracked construction plant must operate safely on temporary ground - and where a geogrid-reinforced granular platform keeps the equipment stable over weak or variable subsoils.
A guided form collects the plant loading, the platform and the ground, then verifies the platform against the selected limit states and returns the required thickness - with the option to save the calculation to a project.

| Method / Check | Scope |
|---|---|
| Working-platform design to BR 470 (ULS & SLS) | Verification of tracked-plant loading on a granular platform over subsoil |
| Punching & bearing/slope failure (GZ1) | Ultimate limit state safety of the platform under the plant loads |
| Settlement & tilting (GZ2) | Serviceability limit state for stable, safe plant operation |
| Geosynthetic reinforcement | Secugrid® and Combigrid® increase bearing capacity and reduce platform thickness |
Naue Platform 2.0 gives engineers a fast, rigorous way to design safe working platforms for heavy tracked plant - verified against punching, bearing failure, settlement and tilting, over layered and weak subsoils. By adding the reinforcement effect of Secugrid® and Combigrid®, it reduces the required platform thickness, cutting aggregate, cost and CO₂ while keeping equipment stable and operations safe. Every design is documented in a downloadable report and backed by Naue's engineering support.
Enter the tracked-plant loading, the granular platform properties and a layered subsoil model. Platform 2.0 then designs the platform for your chosen limit states.
Practical advantages:

Platform 2.0 checks the platform against the limit states that matter for tracked plant:

Platform 2.0 documents and connects the result:

For planners and design engineers: a rigorous working-platform design to ULS and SLS with layered subsoil, multiple load cases and geogrid reinforcement, fully documented. The Naue Engineering and Design Deparmtne (EDD) provides project-specific review and support.
For contractors and site managers: a safe, verified platform thickness for crawler cranes and rigs - thinner where geogrids allow, meaning less aggregate and a clear basis for safe plant operation.
For project owners and clients: documented safety and serviceability for temporary works, with reduced material use and CO₂ - lower risk and a more sustainable site.
| Naue EDD | Project-specific review, verification and design support |
| Platform 2.0 applies the established BR 470 working-platform design method for tracked plant, combined with the measured performance of Naue geogrids. Where a project needs individual review, the Naue Engineering and Design Department (EDD) supports designers and contractors with project-specific design. |
Naue Platform 2.0 is a free online calculator in the Naue Portal DesignSuite that designs temporary working platforms and foundation pads for tracked construction plant, verifying them against ultimate and serviceability limit states and including the reinforcement effect of Secugrid® and Combigrid®.
It checks GZ1 (ULS) - safety against punching and bearing (slope) failure - and, optionally, GZ2 (SLS) - settlement and tilting - so the platform is both strong enough and stable enough for the plant.
For designing temporary working platforms and pads that carry tracked plant such as crawler cranes and piling or drilling rigs, particularly on weak or layered subsoils.
The verification type, the track loading (track width, spacing and edge distance, with two load cases of track length and contact pressure), the platform material, friction angle and unit weight, a layered subsoil model (undrained shear strength, stiffness, depth and water table), and the Secugrid®/Combigrid® reinforcement.
They reinforce the granular platform, spreading the concentrated track loads and increasing bearing capacity. This allows a thinner platform for the same safety, reducing aggregate use and cost.
Yes. You can define up to five subsoil layers with their strength, stiffness and depth and include the water table, and the design considers two track load cases.
You receive a statement of whether a platform is required, the required platform thickness with the limit-state verifications and a downloadable report, and you can save the calculation to a project in the Naue Portal.
Platform 2.0 is free within the Naue Portal and requires a portal login. It is aimed at design engineers, temporary-works designers, contractors and project owners; the Platform Pro variant adds multiple platforms, cost and environmental-impact evaluation.